- Email Maintainer
-
LTE-P-7 IEC AEM SOP
A procedure for measuring the ion exchange capacity (IEC) of an anion exchange membrane (AEM). This is done via a titration method (automated or manual). The SOP was prepared by Yushan Yan, Santiago Rojas-Carbonell, Brian Setzler, Matthew Ueckermann, Kelly M. Meek.
Dataset reference (includes resource metadata): https://www.osti.gov/dataexplorer/biblio/dataset/1983663.
This dataset is cited by: Wang, L, et al. 2022. Standard Operating Protocol for Ion-Exchange Capacity of Anion Exchange Membranes. Front. Energy Res., 03 May 2022, Sec. Process and Energy Systems Engineering, Volume 10. https://www.frontiersin.org/articles/10.3389/fenrg.2022.887893/full.
Resource Metadata
| literature doi | doi.org/10.17025/1983663 |
|---|---|
| metadata modified | fyrir 2 árum |
| mimetype | application/pdf |
| size | 260,6 KiB |
| Síðast uppfært | 20. febrúar 2021 |
|---|---|
| Stofnað | 15. janúar 2021 |
| Skráasnið | application/pdf |
| Leyfisskilmálar | Leyfi ekki tilgreint |