-
Nanoporous TiO2-Water Interface Training Data
2 ResourcesTraining data for the nanoporous TiO2-Water Deep Potential The primary goal of this dataset is to provide high-quality training data for the development of Deep Potential (DP)... -
PEC Performance Measures from Literature Reports
1 ResourceThis dataset is a capture of PEC experimental performance metrics data aggregated from publications and included here in the measurement and format provided by the authors. The... -
2023 HydroGEN New Project Kickoff Meeting
15 ResourcesThe kickoff meeting of the 3rd round of HydroGEN FOA projects was held at NREL August 21-22, 2023, in a hybrid in-person and virtual format. Eleven new DOE-awarded projects... -
Demo: SCPD Data Tool
7 ResourcesSemiconductor Stability Phase Diagram is a data tool created by LLNL and implemented by NREL NOTE: There are a specific set of files required with a specific naming convention,... -
Photoelectrochemically Self-Improving Si/GaN Photocathode
12 ResourcesThe resources are raw data for plotting the figures presented in the paper. These excel files includes the data of: photocurrent density vs voltage (J-V curves), photocurrent vs... -
fig4a
4 ResourcesCalculated formation energy of (0001 ̅) c-plane GaN surfaces. The density-functional theory (DFT) calculations were performed with the generalized gradient approximation, using... -
fig1a
6 Resources10 hours chronoamperometry (CA) testing under 1 sun illumination and constant bias at -0.6 V vs RHE, the corresponding Faradaic efficiency reveals a self-improving nature of... -
fig4b
4 ResourcesCalculated formation energy of (1010 ̅) m-plane GaN surfaces. The density-functional theory (DFT) calculations were performed with the generalized gradient approximation, using... -
fig1b
4 ResourcesAccelerated CA testing on bare epilayer Si/GaN photocathode at constant bias of -0.6 V vs RHE under 3.5 sun illumination for 150 hours in 0.5 M H2SO4 (pH=0.4) -
fig1c
11 ResourcesIntermittent chronoamperometry (CA) testing was performed on Si/GaN photocathode in hourly manner. The LSV scan at 0 hour, 1 hour CA, 2 hours CA, 3 hours CA, 4 hours CA, 6 hours... -
fig1d
9 ResourcesFig1d results were obtained using a 3-electrode configuration with IrOx as the counter electrode and saturated calomel electrode as the reference electrode. Two Si/GaN... -
fig2b
5 ResourcesPhotoconductive atomic force microscopy (PC-AFM) measurements were conducted on Si/GaN samples. PeakForce TUNA mode was used to acquire the morphology and current... -
fig2d
5 ResourcesAfter 10 hrs of chronoamperometry (CA) photoconductive atomic force microscopy (PC-AFM) measurements were conducted on Si/GaN samples using a commercial AFM system (Bruker... -
fig3f
8 ResourcesXPS of Si/GaN photocathode after 10 hour chronoamperometry (CA) testing. Surface chemical composition and valence band structure of GaN were obtained by X-ray photoemission... -
fig3e
8 ResourcesXPS of Si/GaN photocathode after 4 hour chronoamperometry (CA) testing. Surface chemical composition and valence band structure of GaN were obtained by X-ray photoemission... -
fig3c
6 ResourcesXPS after 0hr of chronoampometry. Surface chemical composition and valence band structure of GaN were obtained by X-ray photoemission spectroscopy (XPS) on a Kratos Axis Ultra... -
fig3d
8 ResourcesXPS of Si/GaN photocathode after 1 hour chronoamperometry (CA) testing. Surface chemical composition and valence band structure of GaN were obtained by X-ray photoemission... -
2018 PEC Benchmarking Questionnaire Summary
3 ResourcesEMN PEC Benchmarking Questionnaire Summary: Includes background, motivation and summary of PEC questionnaire responses.